Adson Extracting Forceps Non-Serrated

$24.50

  • Atraumatic hair graft forceps for Hair Restoration, Plastic & Reconstructive, and Dermatologic Surgery
  • Smooth Flat-Faced Non-Serrated Opposing Tips; Fine Point Closure for Single Follicular Unit Grasping Without Crush Injury
  • Spring-Action Flat Handle (No Ring); Thumb & Finger Compression Grip
  • Scalp Follicular Units, Hair Grafts (Single, Double & Multi-Follicular Units)
  • Fine Tapered Atraumatic Tips
  • Available in 40°, 45°, 55°
  • Available in 6 mm, 8 mm, 10 mm — Spring-Action Flat Handle (No Ring)
  • 12 cm overall length
  • 420-Series Martensitic German Steel — Satin / Non-Reflective
  • Advanced corrosion resistance from validated surface treatment
  • Reusable (Autoclavable & Sterilizable)
  • Comprehensive Lifetime Warranty
  • ISO 13485, CE, FDA, NMPA
SKU: N/A Category: Tags: ,
Secure Payment Methods
Description

Follicular Unit Graft Extraction and Recipient Site Placement in Hair Restoration Surgery

The Adson Extracting Forceps is an Adson-type straight, flat-profile spring-action thumb forceps in the Tissue Grasping Instruments category manufactured by BusinessMed Instruments®, Hair Restoration Forceps / Graft Handling Forceps sub-category, used in Hair Restoration Surgery, Plastic & Reconstructive Surgery, and Dermatologic Surgery.

The Adson Extracting Forceps grasps and transfers follicular unit grafts — full-thickness skin grafts containing epidermis, dermis, subcutaneous adipose tissue layer, erector pili muscle insertion, and perifollicular neurovascular network — across the safe donor area of scalp and recipient site scalp in Follicular Unit Extraction (FUE), Follicular Unit Transplantation (FUT), Hair Graft Handling, Graft Implantation, and Recipient Site Placement.

Smooth Flat-Faced Non-Serrated Opposing Tips

The Smooth Flat-Faced Non-Serrated Opposing Tips contact the follicular unit graft surface without introducing serration-point compression force against hair matrix cells. Fine Point Closure is achieved at the subcutaneous fat layer — at 2–3 mm punch insertion depth — distributing contact load across the full graft contact surface rather than concentrating force at discrete tooth contacts. The None — Non-Serrated (Smooth Jaw Faces Throughout Full Tip Length) configuration and None — Toothless Configuration eliminate the compressive geometry that elevates follicular crush injury and graft transection rate.

Spring-Action Flat Handle (No Ring)

The Spring-Action Flat Handle (No Ring) with Thumb & Finger Compression Grip returns the Fine Tapered Atraumatic Tips to an open resting position between each graft contact. The surgeon modulates compression force incrementally through the Thumb & Finger Compression Grip, enabling mid-extraction assessment of follicular unit release status before full extraction force is applied. The absence of a ring constraint permits immediate release of grip pressure, removing sustained mechanical load from hair matrix cells during the extraction sequence.

Follicular Unit Graft Viability and Intraoperative Consequence

The follicular unit graft undergoes revascularisation from the recipient bed dermis following implantation; the perifollicular neurovascular network re-integrates with recipient tissue, and follicle survival depends on minimising ischaemic time and mechanical trauma during handling. BusinessMed® Adson Extracting Forceps addresses four named mechanical failure modes: follicular crush injury — mechanical compression of hair matrix cells by serrated or high-pressure jaw contact resulting in non-viable grafts; graft capping — forceps applied at epidermal level rather than fat layer, leaving the follicle root in the scalp; follicular transection — shear force applied when the punch has not adequately released the follicular unit, elevating the follicular transection rate (FTR) above the clinically established 5% acceptable threshold; and surrounding follicular unit damage from incorrect tip angle placement in the occipital scalp donor region. The None — Smooth Tip Design Preserves Follicle Integrity directly addresses the crush-injury mechanism. The spring-action grip feedback enables the surgeon to determine whether single-stage or multi-stage extraction is needed before extraction force is completed. The 5% FTR benchmark, originally established in FUT strip harvesting at a skilled technician baseline of 2–5%, applies equally to FUE with forceps; the full-thickness graft structure — including erector pili muscle insertion and perifollicular neurovascular network — constitutes the complete biological complex whose viability depends on atraumatic forceps technique.

Technical Specifications

Attribute BusinessMed Specification
Manufacturer / Brand BusinessMed Instruments®
Author / Inventor Adson
Instrument Type Adson Extracting Forceps
Product Type Hair Graft Extracting Forceps / Non-Serrated Thumb Forceps
Product Category Tissue Grasping Instruments
Product Sub-Category Hair Restoration Forceps / Graft Handling Forceps
Surgical Disciplines Hair Restoration Surgery, Plastic & Reconstructive Surgery, Dermatologic Surgery
Procedural Indication Follicular Unit Extraction (FUE), Follicular Unit Transplantation (FUT), Hair Graft Handling, Graft Implantation, Recipient Site Placement
Anatomical Target Scalp Follicular Units, Hair Grafts (Single, Double & Multi-Follicular Units)
Design / Shape Straight, Flat-Profile Spring-Action Thumb Forceps with Tapered Tip
Tip Shape Fine Tapered Atraumatic Tips
Tip Profile Non-Serrated, Smooth Flat-Faced Tips for Atraumatic Graft Handling
Serration Type None — Non-Serrated (Smooth Jaw Faces Throughout Full Tip Length)
Number of Teeth None — Toothless Configuration
Tooth Configuration None — Smooth Tip Design Preserves Follicle Integrity
Working End Detail Smooth Flat-Faced Non-Serrated Opposing Tips; Fine Point Closure for Single Follicular Unit Grasping Without Crush Injury
Handle Type Spring-Action Flat Handle (No Ring); Thumb & Finger Compression Grip
Overall Length 120 mm (12 cm)
Available Tip Platform Length Available in 6 mm, 8 mm, 10 mm
Tip Angle Available in 40°, 45°, 55°
Material Grade 420-Series Martensitic German Steel
Material Composition German Surgical-Grade Stainless Steel
Finish Satin / Non-Reflective
Passivation Validated Protocol (Advanced Corrosion Resistance)
Reprocessing Standard Validated HTM 01-01 / ISO 17664 Protocol
Certifications ISO 13485, CE, FDA, NMPA
Sterility Non-Sterile
Reusable Yes (Autoclavable & Sterilizable)
Warranty Comprehensive Lifetime Warranty

Clinical Uses and Applications

  • The follicular unit graft is extracted from the safe donor area of scalp in Follicular Unit Extraction (FUE) to preserve perifollicular neurovascular network integrity.
  • The scalp follicular unit is grasped at the subcutaneous adipose tissue layer level in FUE to keep follicular transection rate below the 5% acceptable threshold.
  • The follicular unit graft is placed into pre-made recipient site incisions in Graft Implantation to complete Recipient Site Placement without crush injury.
  • Single, Double, and Multi-Follicular Units are handled in Hair Graft Handling to maintain graft viability during transfer between donor site and holding medium.
  • Tip angle (40°, 45°, or 55°) is selected in FUE to match follicular angle geometry in the occipital scalp donor region.
  • Tip platform length (6 mm, 8 mm, or 10 mm) is selected across FUE and FUT procedures to match graft size and access geometry.
  • The follicular unit graft is grasped and positioned in Follicular Unit Transplantation (FUT) following strip dissection for recipient site placement at the scalp.
  • Hair grafts are handled in Dermatologic Surgery graft procedures to prevent surrounding follicular unit damage during atraumatic transfer.

Associated Instruments

  • Manual Punch (circular hollow punch, 0.7–1.0 mm diameter) — used in the same operative sequence in Follicular Unit Extraction (FUE); scores and releases the follicular unit from surrounding scalp tissue immediately prior to forceps extraction.
  • Sharp Circular Punch — used in FUE (SAFE System, step 1); incises skin circumferentially around the follicular unit before blunt dissection and forceps extraction.
  • Blunt Circular Punch (SAFE System) — used in FUE (SAFE System, step 2); loosens the follicular unit from surrounding tissue before forceps extraction.
  • Fine-toothed traction forceps (0.1 mm) — used in the same extraction sequence in two-forceps technique; lifts dermis to expose the follicular unit while the extraction forceps removes the graft.
  • Implanter Pen — used in the recipient site placement phase as an alternative or adjunct to forceps-only placement in FUE and FUT.
  • Powered SafeScribe® — motorised punch device used in the extraction phase; forceps complete extraction after powered punch scoring.

Frequently Asked Questions

What distinguishes a non-serrated forceps from a serrated forceps for follicular unit graft extraction?

BusinessMed® Adson Extracting Forceps uses Smooth Flat-Faced Non-Serrated Opposing Tips that distribute grip force across the full graft contact surface. Serrated jaws concentrate compressive force at discrete tooth contacts, increasing the risk of follicular crush injury — mechanical compression of hair matrix cells that produces non-viable grafts. The None — Non-Serrated (Smooth Jaw Faces Throughout Full Tip Length) configuration addresses this mechanism directly, targeting maintenance of follicular transection rate below the 5% acceptable threshold.

At what depth should the forceps engage the follicular unit graft during FUE extraction?

The Fine Tapered Atraumatic Tips of the Adson Extracting Forceps are positioned at the subcutaneous adipose tissue layer — corresponding to 2–3 mm punch insertion depth. Grasping at epidermal level rather than fat layer produces graft capping, leaving the follicle root in the scalp. Tip angle selection (40°, 45°, or 55°) is determined by follicular angle geometry in the occipital scalp donor region at each extraction site.

How does the spring-action handle assist intraoperative decision-making during extraction?

The Spring-Action Flat Handle (No Ring) with Thumb & Finger Compression Grip returns the tips to an open resting position between graft contacts. This allows the surgeon to assess whether the follicular unit has been adequately released by the punch before applying full extraction force, enabling a decision between single-stage and multi-stage extraction. The absence of a ring constraint permits immediate, unrestricted release of grip pressure at any point in the extraction sequence.

Which tip platform length and tip angle are appropriate for different graft sizes and follicular angles?

BusinessMed® Adson Extracting Forceps is available in 6 mm, 8 mm, and 10 mm tip platform lengths and 40°, 45°, and 55° tip angles. Tip platform length is selected to match graft size and access geometry. Tip angle is selected to align with the follicular unit angle in the safe donor area of scalp — the occipital scalp donor region — and in the recipient site scalp during Graft Implantation and Recipient Site Placement.

Is the instrument compatible with autoclave sterilization and validated reprocessing protocols?

The Adson Extracting Forceps is reusable and rated Yes (Autoclavable & Sterilizable). The instrument is validated against the Validated HTM 01-01 / ISO 17664 Protocol. It is supplied Non-Sterile and is reprocessed according to the facility’s validated decontamination cycle prior to each use across Hair Restoration Surgery, Plastic & Reconstructive Surgery, and Dermatologic Surgery applications.

Can this forceps be used in both FUE and FUT procedures?

BusinessMed® Adson Extracting Forceps is indicated for Follicular Unit Extraction (FUE) and Follicular Unit Transplantation (FUT), as well as Hair Graft Handling, Graft Implantation, and Recipient Site Placement. In FUT, the same fat-level grasping technique — using the Smooth Flat-Faced Non-Serrated Opposing Tips at the subcutaneous adipose tissue layer — applies to grafts prepared by strip dissection. All graft sizes from single to multi-follicular units (1–4 hairs per follicular unit) are within the instrument’s indicated anatomical target range.

What warranty applies to this instrument?

Adson Extracting Forceps carries a Comprehensive Lifetime Warranty. Buyers should confirm warranty scope and terms with BusinessMed Instruments® directly before procurement decisions are finalized.

Clinical References

  • Follicular Unit Extraction — StatPearls
    NBK547740
  • Hair Transplantation — StatPearls
    NBK547740
    (FUE technique, forceps handling, FTR threshold)
  • Follicular Unit Hair Transplantation —
    PubMed
  • Atraumatic Graft Handling in Follicular Unit Extraction —
    PubMed
  • Follicular Transection Rate and Instrumentation in FUE —
    PubMed
Shipping & Delivery

Global Shipping Services with Trusted Carriers
We proudly offer dependable international shipping through our trusted logistics partners: DHL, FedEx, UPS, and DPEX. These collaborations ensure your orders are delivered safely and on time, no matter where you are in the world.

No Hidden Customs Fees or Delivery Charges
To provide you with a hassle-free experience, we manage all customs-related processes in advance. You won’t face any unexpected customs duties or additional charges when your order is delivered.

Fast Dispatch for In-Stock Products: Ships in 3–4 Business Days
For products currently available in our inventory, we ensure swift dispatch within 3 to 4 business days from the date of your order. Your convenience and satisfaction remain our top priorities.

Pre-Order Dispatch Timeline: Ships in 15 Business Days
Pre-order items are prepared and shipped within 15 business days. This processing time allows us to ensure quality and accuracy before your order is dispatched.

Order Tracking Made Simple: Email and Website Access
Once you place your order, you’ll receive an invoice and a unique Order ID via email. To track your order’s status at any time, click the “TRACK ORDER” option located above the menu on our website.

Real-Time Shipment Tracking via Email Notification
As soon as your order is shipped, we’ll email you a tracking number so you can monitor its progress. You can also request your tracking number by contacting us at [email protected] or through WhatsApp at +92 321 8613008.

Special Requests: Low-Value Invoices & Gift Marking Available
If you need your parcel to be marked as a gift or require a low-value invoice to ease customs processing, simply send us an email with your request. Our team is happy to accommodate these needs where possible.

Access to Past Orders and Invoices via Your Account
Keep your transaction history organized by logging into your account on our website. Here, you can view all your previous orders and download related invoices whenever needed.

Efficient Inventory Across Domestic Warehouses
Our well-organized domestic warehouses allow us to process orders efficiently. While we strive to avoid delays, unforeseen events may occasionally impact shipping timelines. Should any issues arise, please don’t hesitate to contact us at [email protected]—we’re here to help.

Your Satisfaction, Our Priority
We are committed to delivering a seamless and professional shipping experience. Our customer service team is always ready to support you with any concerns or special requests.

RETURNS & REPLACEMENT

Return and Replacement

At BusinessMed Instrument, we prioritize quality, which means that the need for returns and replacements is infrequent. Each instrument is thoroughly inspected and approved by our specialists before shipment, ensuring that it adheres to our rigorous standards. Any instruments that fall short of these criteria are refurbished in our workshop to surpass expectations.

  • Inspect Your Package: When you receive your package, please examine it carefully for any damages or unsatisfactory conditions. If you notice any issues, contact us within 15 days of delivery at [email protected]. We will either replace the product or issue a credit for your purchase within 7 business days, including all shipping fees to your address.
  • Non-Damaged Returns: If a customer wishes to return items that are not damaged, BusinessMed Instrument is not obligated to accept the return unless the issue is due to our mistake, such as incorrect quantities or items sent.
  • Return Process: To start a return, please visit our website at https://businessmedinstruments.com/contact-us/ and fill out the form, providing the reason for your return. Our dedicated team will address your concerns and resolve your issue within 48 hours.
  • Exceptional Standards: We take pride in the quality of our instruments. Each item is crafted and inspected with great attention to detail, minimizing the chance of returns and ensuring customer satisfaction.
  • Customer-Centric Approach: At BusinessMed Instrument, your experience is our top priority. Whether you encounter a rare issue or have a question, our team is here to help, ensuring a smooth process.

Our returns and replacements policy underscores our commitment to providing the highest quality surgical instruments while delivering outstanding customer support.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Adson Extracting Forceps Non-Serrated”